| MODEL | JTH-20L-70- CPA/W | JTH-30L-70- CPA/W | JTH-64L-70- CPA/W | JTH-80L-70- CPA/W | JTH-150L-70- CPA/W | |
| Chamber Design | ||||||
| Internal Volume | L | 20 | 30 | 64 | 80 | 150 |
| Internal Dimensions (cm) | W | 34 | 30 | 40 | 40 | 50 |
| H | 15 | 40 | 40 | 50 | 60 | |
| D | 40 | 25 | 40 | 40 | 50 | |
| External Dimensions (cm) | W | 50 | 85 | 56 | 60 | 70 |
| H | 86 | 100 | 105 | 146 | 156 | |
| D | 86 | 65 | 85 | 123 | 133 | |
| Temperature Test Parameters | ||||||
| Temperature Range | °C | -70 ℃/-40 ℃~85 ℃/120 ℃/150 ℃/180 ℃ or customized | ||||
| Heating Rate | °C/min | 1 ℃/min (empty load) or customized | ||||
| Cooling Rate | °C/min | 3 ℃/min (empty load) or customized | ||||
| Temperature Fluctuation | °C | ±0.5 | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Temperature Uniformity | °C | ≤ 2.0 (unloaded, constant state) | ||||
| Temperature Deviation | °C | ±2 | ±2 | ±2 | ±2 | ±2 |
| Humidity Test Parameters | ||||||
| Humidity Range | %RH | 20%~95% | ||||
| Humidity Deviation | %RH | ± 3.0% RH when>75% RH, ± 5.0% RH when ≤ 75% RH | ||||
| Humidity Fluctuation | %RH | ±2 | ±2 | ±2 | ±2 | ±2 |
| Humidity Uniformity | %RH | 5 | 5 | 5 | 5 | 5 |
| Power supply and Connection (Subject To Actual Usage Configuration) | ||||||
| Configure Interface | Standard RS485 port/USB, optional WLAN and APP functions, with power on test hole | |||||
| Rated Voltage | V/Hz | AC380V 50HZ | ||||
| PLC Function | Automatically call group PID parameters | |||||
| Protector | Imported over temperature protection, dry burning protection, humidification protection, overload protection, high voltage protection, leakage protection | |||||
| Control Mode | PID+SSR | |||||
| Environmental Temperature/Humidity For Use | 5℃~35℃;≤ 85%RH | |||||
| System Components | ||||||
| Material Science | Shell Material | Cold rolled steel plate electrostatic double-sided spray coating | ||||
| Inner Liner Material | SUS # 304 stainless steel plate | |||||
| Thermal Insulation Material | 150mm hard polyurethane foam insulation layer | |||||
| Refrigeration System | Cooling Method | Mechanical binary freezing method (air-cooled/water-cooled) | ||||
| Compressor | Full density vortex compressor | |||||
| Refrigerant | R404a, R23 environmentally friendly refrigerant | |||||
| Heating System | Finned nickel chromium alloy electric heating tube | |||||
| Circulating Fan | Adopting a multi blade centrifugal circulating fan with reinforced shaft and aluminum alloy rotating blades that are resistant to high and low temperatures | |||||
| Door Observation Window | A 3-layer vacuum glass observation window for heat and sweat prevention; Door frame electric heating (automatic adjustment) anti frost and anti condensation device | |||||
| Temperature Sensor | Platinum resistance PT100 | |||||
| Humidity Sensor | Dry wet bulb sensor | |||||
| Temperature/Humidity Controller | High precision resistive touch screen, can be controlled by a USB external mouse; Historical curve record, PID+SSR/SCR automatic bidirectional synchronous output | |||||
| Noise | dB(A) | ≤ 70dB (A-level sound level) | ||||
| Net Weight | KG | Based on the actual customized weight, the ground load requirement for the venue is ≥ 1000kg/㎡ | ||||
| Enclosure | Double opening imported hinged door, 1 observation window, 1 built-in slope, customized operation hole, overflow hole, lighting, air pressure balance device, etc | |||||