The Rain Spray Test Chamber is used to evaluate the waterproof performance of products under simulated moderate rainfall conditions. It supports IPX3 and IPX4 protection grade testing, applying oscillating tube and swinging spray systems to expose samples to multidirectional water sprays. Ideal for testing electrical devices, lighting equipment, and outdoor electronics, the system ensures products can withstand environmental water exposure during operation or storage. It complies with IEC 60529 and GB/T 4208, and is essential for product design validation, quality control, and certification.
| Height | 100 |
|---|
The IPX3/IPX4 Rain Test Chamber is designed to simulate moderate to heavy rain or splashing water conditions to evaluate the water ingress protection of products. Complying with IEC 60529 and GB/T 4208 standards, this chamber enables reliable testing of enclosures and components subjected to angled spraying (IPX3) and splashing from all directions (IPX4).
It provides a controlled environment to verify product sealing effectiveness, especially for consumer electronics, automotive parts, lighting devices, smart appliances, and industrial control systems. The chamber supports both oscillating spray pipe and hand-held spray nozzle methods, offering flexibility for a wide range of product sizes and shapes.
Features:
Dual IP Testing Modes
Swing pipe spray (oscillating tube) for IPX3 and IPX4
Hand-held nozzle option included for enhanced test versatility (IPX4 only)
Precise Spray Simulation
Adjustable spray aperture spacing and nozzle angles
Uniform water distribution to replicate real-world rain impact scenarios
Programmable and Automated Operation
Easy-to-set test durations and spray pipe angles
Optional automatic oscillation angle control system for repeatable testing
Rotary Turntable with Load Capacity
Smooth, adjustable-speed rotation for samples up to 20 kg
Supports 200 mm spray distance with customizable height and position
Sturdy and Corrosion-Resistant Structure
SUS#304 stainless steel interior for long-lasting operation
Cold-rolled or stainless steel outer shell with protective coating
Integrated Safety System
Includes protection for power overload, grounding, water shortage, and audible alarms for abnormal conditions
Ideal for Certification and R&D
Widely used in waterproof IP testing, product validation, and design verification phases
| MODEL | JT-IPX34-225 | JT-IPX34-500 | JT-IPX34-1000 | JT-IPX34-1400 | |
| Chamber Design | |||||
| Internal Volume | L | 225 | 500 | 1000 | 1400 |
| Internal Dimensions (cm) | W | 60 | 80 | 100 | 140 |
| H | 60 | 80 | 100 | 140 | |
| D | 60 | 80 | 100 | 140 | |
| External Dimensions (cm) | W | 90 | 110 | 120 | 190 |
| H | 165 | 175 | 195 | 235 | |
| D | 108 | 148 | 150 | 160 | |
| Swing Tube Diameter | mm | 200 | 300 | 400 | 600 |
| Rotary Disc Diameter | mm | 300 | 400 | 500 | 500 |
| Rotary Table Load Capacity | kg | 20 | 20 | 20 | 20 |
| Experimental Parameters | |||||
| Adjustable Height Of Turntable | mm | 100 | 100 | 100 | 100 |
| Drip Hole Diameter | mm | ∅0.4 | ∅0.4 | ∅0.4 | ∅0.4 |
| Spray Aperture Spacing | mm | 50 | 50 | 50 | 50 |
| Sample Rack Rotation Speed | 1~3r/min (adjustable) | ||||
| Spray Hole Flow Rate | 0.07 L/min +5% | ||||
| Rainwater Pressure | 220V 50HZ80~150Kpa | ||||
| Swing Angle Range Of Sprinkler Pipe | 120 °, 320 ° (close) | ||||
| Nozzle Angle | 120 ° (IPX3), 180 ° (IPX4) | ||||
| Swing Angle | 120 ° (IPX3), 320 ° (IPX4) | ||||
| Pipe Swing Amplitude | Maximum ± 180 ° (close) | ||||
| Swing Speed Of Sprinkler Pipe | 3KWIPX3 15 times/min; IPX4 5 times/min | ||||
| Pre Set Test Time | 1S~9999H59M59S can be adjusted freely | ||||
| Power Supply And Connection | |||||
| Power Supply | 220V 50HZ | 220V 50HZ | 220V 50HZ | 220V 50HZ | |
| Power | 3KW | 3KW | 3KW | 3KW | |
| Environment Condition | Temperature 5 ℃~40 ℃ Relative temperature ≤ 85% RH | ||||
| System Components | |||||
| Material Science | Outer Box Material | SUS#304 stainless steel or cold rolled plate baked paint | |||
| Inner Box Material | SUS#304 stainless steel | ||||
| Control System | Independently developed control system | ||||
| Safety Device | Power overload/short circuit protection, grounding protection, water shortage protection, alarm sound prompt | ||||